Xylene-Free Clearing Reagent

XUP xylene-free clearing reagent, 1000 mL bottle and 5 L container

Xylene-Free Clearing Reagent

XUP™

A hydrocarbon-based clearing reagent for tissue processing and slide staining. XUP™ replaces xylene in most histology and cytology protocols without significant procedural changes.

Pre-launch samples from November 2026 · Official launch January 2027
Catalog No.SizePack
FSOL10101000 mL4 / case
FSOL10381 gal4 / case
FSOL10505 L4 / case
FSOL10205 galCube
  • Removes xylene from clearing and staining. No xylene at the tissue processor, the staining line, or in the waste container.
  • Lower vapor pressure. 0.15 kPa or less at 20 °C, compared with roughly 0.8 kPa for xylene, so less solvent evaporates into the room air.
  • Not classified for acute toxicity. Oral, dermal, and inhalation acute toxicity are not classified (SDS Section 11).
  • Drop-in workflow. Uses the same clearing steps as xylene. Before you switch, our technical team confirms protocol settings for your exact processor model and matches your current staining.
CompositionPetroleum-based hydrocarbon mixture (UVCB)
Appearance / odorLiquid / characteristic
Flash point (closed cup)Below 50 °C (122 °F), ASTM D93
Boiling range175–260 °C (347–500 °F)
Vapor pressure≤ 0.15 kPa at 20 °C
Relative density0.70–0.80 at 20 °C
Viscosity1.6–3.0 cSt at 40 °C
Water solubilityInsoluble
StorageCool, well-ventilated area, container tightly closed, away from ignition sources
Shelf life2 years from date of manufacture. Use within 90 days of opening is recommended.
Signal wordDanger
Hazard statementsH226, H304, H315, H413
NFPA (Health / Fire / Reactivity)1 / 2 / 0
DOT / IATA / IMDGUN1268, Petroleum distillates, n.o.s., Class 3, PG III. Limited Quantity provisions may apply.
WasteFlammable liquid. Manage as ignitable hazardous waste under local, state, and federal regulations.
Tissue processorsIn routine use by laboratories on Leica, Sakura, Dakewe, Diapath, and Epredia tissue processors. These are user-reported installations, not validations by the equipment manufacturers.
Protocol setupRequired before switching: contact our technical team with your exact processor model. Settings are confirmed for your instrument and workflow.
StainingCompatible with H&E, special stains, and IHC.
Mounting mediaXUP™ Mount (xylene-free mounting medium).

This is the fact

The only way to truly eliminate xylene exposure in the laboratory is to eliminate xylene itself.

Request an Evaluation Sample

Your first step to eliminating xylene from the lab.